When building leaf and spine networks, leafs connect to spines, but leafs don’t connect to leafs, and spines don’t connect to spines. There are exceptions to this and vPC is one of those exceptions. The leafs that are going to be part of the same vPC need to connect to each other. There are two ways of achieving this:

  • Physical interfaces.
  • Fabric peering.

We will first use physical interfaces and then later remove that and use fabric peering. Now, my lab is virtual so take physical with a grain of salt, but they will be dedicated interfaces. The following will be required to configure vPC:

  • Enable vPC.
  • Enable LACP.
  • Create vPC domain.
  • Create a VRF for the vPC peer keepalive.
  • Configure the interface for vPC peer keepalive.
  • Configure the vPC peer keepalive.
  • Configure the vPC peer link interfaces.
  • Configure the vPC peer link.

This is shown below:

The vPC is now up:

Leaf1# show vpc
Legend:
                (*) - local vPC is down, forwarding via vPC peer-link

vPC domain id                     : 1   
Peer status                       : peer adjacency formed ok      
vPC keep-alive status             : peer is alive                 
Configuration consistency status  : success 
Per-vlan consistency status       : success                       
Type-2 consistency status         : success 
vPC role                          : primary                       
Number of vPCs configured         : 0   
Peer Gateway                      : Disabled
Dual-active excluded VLANs        : -
Graceful Consistency Check        : Enabled
Auto-recovery status              : Disabled
Delay-restore status              : Timer is off.(timeout = 30s)
Delay-restore SVI status          : Timer is off.(timeout = 10s)
Delay-restore Orphan-port status  : Timer is off.(timeout = 0s)
Operational Layer3 Peer-router    : Disabled
Virtual-peerlink mode             : Disabled

vPC Peer-link status
---------------------------------------------------------------------
id    Port   Status Active vlans    
--    ----   ------ -------------------------------------------------
1     Po12   up     1,10,20,100                                                          

Note that the following needs to be consistent when using vPC in VXLAN network:

  • Same VLAN-to-VNI mapping on both peers.
  • SVI present for VLANs mapped to VNI on both peers.
  • VNIs need to use the same BUM mechanism such as multicast or ingress replication.
  • If using multicast, both must use the same multicast group.

If the consistency check fails, NVE loopback interface is shutdown on switch in vPC secondary role.

Now let’s connect a host using vPC.

Setting up Bond and LACP on Linux Host

I’m using an Ubuntu host that we will use to setup the following:

  • Create a YAML file for the network configuration to supply to Netplan.
  • Bond two interfaces, ens192 and ens224, into a bond.
  • Enable LACP on the interfaces.
  • Configure the hashing policy to use both L3 and L4 information.
  • Add a route for 198.51.100.0/24 via 10.0.0.1.

On my host, the YAML file is in /etc/netplan/:

server3:~$ cd /etc/netplan/
server3:/etc/netplan$ ls
01-network-manager-all.yaml

The file right now is very bare bones:

server3:/etc/netplan$ cat 01-network-manager-all.yaml 
# Let NetworkManager manage all devices on this system
network:
  version: 2
  renderer: NetworkManager

Before messing with system configuration it’s always good to take a backup:

server3:/etc/netplan$ sudo cp 01-network-manager-all.yaml 01-network-manager-all-backup.yaml
server3:/etc/netplan$ ls
01-network-manager-all-backup.yaml  01-network-manager-all.yaml

Now we add the following YAML file:

network:
  version: 2
  renderer: NetworkManager
  ethernets:
    ens192:
      dhcp4: no
    ens224:
      dhcp4: no
  bonds:
    bond0:
      interfaces: [ens192, ens224]
      addresses: [10.0.0.33/24]
      routes:
      - to: 198.51.100.0/24
        via: 10.0.0.1
      parameters:
        mode: 802.3ad
        transmit-hash-policy: layer3+4
        mii-monitor-interval: 1
      nameservers:
        addresses:
          - "8.8.8.8"
          - "9.9.9.9"

Before applying the configuration, I will add the vPC on LEAF1 and LEAF2. The commands needed are shown below:

Now let’s update the network configuration on the Ubuntu host:

server3:/etc/netplan$ sudo netplan apply

The vPC is now up on LEAF1:

Leaf1# show port-channel summary interface port-channel 33
Flags:  D - Down        P - Up in port-channel (members)
        I - Individual  H - Hot-standby (LACP only)
        s - Suspended   r - Module-removed
        b - BFD Session Wait
        S - Switched    R - Routed
        U - Up (port-channel)
        p - Up in delay-lacp mode (member)
        M - Not in use. Min-links not met
--------------------------------------------------------------------------------
Group Port-       Type     Protocol  Member Ports
      Channel
--------------------------------------------------------------------------------
33    Po33(SU)    Eth      LACP      Eth1/7(P)        

Leaf1# show lacp port-channel interface port-channel 33
port-channel33
  Port Channel Mac=0-ad-e6-88-1b-8
  Local System Identifier=0x8000,0-ad-e6-88-1b-8
  Admin key=0x8021
  Operational key=0x8021
  Partner System Identifier=0xffff,82-8b-b6-cf-ba-df
  Operational key=0xf
  Max delay=0
  Aggregate or individual=0
  Member Port List=Eth1/7 

The bond0 interface can now be seen on the host:

server3:/etc/netplan$ ip addr
<SNIP>
5: bond0: <BROADCAST,MULTICAST,MASTER,UP,LOWER_UP> mtu 1500 qdisc noqueue state UP group default qlen 1000
    link/ether 82:8b:b6:cf:ba:df brd ff:ff:ff:ff:ff:ff
    inet 10.0.0.33/24 brd 10.0.0.255 scope global noprefixroute bond0
       valid_lft forever preferred_lft forever
    inet6 fe80::808b:b6ff:fecf:badf/64 scope link 
       valid_lft forever preferred_lft forever

We can get some more information using cat /proc/net/bonding/bond0:

cat /proc/net/bonding/bond0
Ethernet Channel Bonding Driver: v6.5.0-25-generic

Bonding Mode: IEEE 802.3ad Dynamic link aggregation
Transmit Hash Policy: layer3+4 (1)
MII Status: up
MII Polling Interval (ms): 1
Up Delay (ms): 0
Down Delay (ms): 0
Peer Notification Delay (ms): 0

802.3ad info
LACP active: on
LACP rate: slow
Min links: 0
Aggregator selection policy (ad_select): stable

Slave Interface: ens192
MII Status: up
Speed: 10000 Mbps
Duplex: full
Link Failure Count: 0
Permanent HW addr: 00:50:56:ad:4f:d3
Slave queue ID: 0
Aggregator ID: 1
Actor Churn State: none
Partner Churn State: none
Actor Churned Count: 0
Partner Churned Count: 0

Slave Interface: ens224
MII Status: up
Speed: 10000 Mbps
Duplex: full
Link Failure Count: 0
Permanent HW addr: 00:50:56:ad:40:5d
Slave queue ID: 0
Aggregator ID: 1
Actor Churn State: none
Partner Churn State: none
Actor Churned Count: 0
Partner Churned Count: 0

One interesting thing to note is that after enabling the bond interface, the individual interfaces ens192 and ens224 now show the same MAC address as the bond0 interface:

server3:/etc/netplan$ ip link
<SNIP>
3: ens192: <BROADCAST,MULTICAST,SLAVE,UP,LOWER_UP> mtu 1500 qdisc fq_codel master bond0 state UP mode DEFAULT group default qlen 1000
    link/ether 82:8b:b6:cf:ba:df brd ff:ff:ff:ff:ff:ff permaddr 00:50:56:ad:4f:d3
    altname enp11s0
4: ens224: <BROADCAST,MULTICAST,SLAVE,UP,LOWER_UP> mtu 1500 qdisc fq_codel master bond0 state UP mode DEFAULT group default qlen 1000
    link/ether 82:8b:b6:cf:ba:df brd ff:ff:ff:ff:ff:ff permaddr 00:50:56:ad:40:5d
    altname enp19s0
5: bond0: <BROADCAST,MULTICAST,MASTER,UP,LOWER_UP> mtu 1500 qdisc noqueue state UP mode DEFAULT group default qlen 1000
    link/ether 82:8b:b6:cf:ba:df brd ff:ff:ff:ff:ff:ff

With vPC configured, in the next blog post we’ll verify connectivity.

Cisco vPC in VXLAN/EVPN Network – Part 2 – Configuring vPC
Tagged on:                 

5 thoughts on “Cisco vPC in VXLAN/EVPN Network – Part 2 – Configuring vPC

  • May 2, 2024 at 1:37 pm
    Permalink

    The step-by-step approach made it easier to understand. Excellent work!

    Reply
  • May 4, 2024 at 12:29 pm
    Permalink

    Great post! I wonder if it makes sense for you to write an article about loop prevention in VXLAN EVPN enviroment eg when there is a classical ethernet network connected on a VXLAN EVPN network.

    Reply
    • May 4, 2024 at 5:41 pm
      Permalink

      Thanks! It might be something I’ll cover in the future.

      Reply
  • May 21, 2024 at 3:50 pm
    Permalink

    It looks like there’s a minor typo in config in the image under the sentence “Before applying the configuration, I will add the vPC on LEAF1 and LEAF2. The commands needed are shown below:”

    Should be port-channel33 rather than port-channel3

    (And wishing these blog posts had existed 3-4 months ago when I had to convert a couple of leaf pairs into vPC pairs! 😉 )

    Reply
    • May 22, 2024 at 6:29 am
      Permalink

      Thanks, Ben! I had some issues setting up the vPC and changed the number of the portchannel. I have updated the post now 🙂

      Reply

Leave a Reply